N0922L, N1322L, F1222L, F1522L

Remote Low Side Service Manual Includes Prodigy Plus

December 2014

Page 31

Repair Procedures: Replace the Evaporator:

(Assuming all the steps for removal of the thrust

bearing, breaker, auger, and water seal have been

performed.)

1. Close ball valves to isolate machine.

2. Recover the refrigerant from the ice maker.

3. Unsweat the refrigerant connections:

• a) At the thermostatic expansion valve outlet. Heat

sink the TXV body when unsweating or resweating

the adjacent tubing.

• b) At the suction line at the joint about 3" from the

evaporator.

4. Remove the evaporator.

5. Unsweat the drier from the liquid line.

6. After installing a new water seal in the new

evaporator (see “To Replace the Water Seal”) sweat

in the new evaporator at the old tubing connections.

7. Install an new drier in the liquid line.

8. Evacuate the system until dehydrated, then weigh

in the nameplate charge. Check for leaks.

9. Install auger, breaker, breaker bearing assembly,

and ice discharge chute in reverse order of

disassembly.

10. Open ball valves.

To Reassemble the Evaporator and Auger

1. After the gear motor has been inspected, fasten the

evaporator to the gear motor. Torque the bolts to 110

inch pounds.

2. Lower the auger into the evaporator barrel, slightly

turning it to match up with the drive end. Do Not Drop

Into the Evaporator.

3. Complete the reassembly by reversing the

disassembly for the breaker & thrust bearing

assembly.