beautypg.com

Scotsman F1222L Service Manual User Manual

Page 18

background image

N0922L, N1322L, F1222L, F1522L

Remote Low Side Service Manual Includes Prodigy Plus

December 2014

Page 18

Water System

Water enters the machine through the 3/8" male flare

at the rear of the cabinet, goes to the water reservoir

which it enters through the float valve.

The float valve maintains a constant level of water in

the reservoir and evaporator, as water flows out the

bottom of the reservoir tank to fill the evaporator.

Reservoir overflow or evaporator condensation is

routed to the drain. Water cooled models have a

separate water circuit for the cooling water: it enters

the fitting at the rear, goes to the water regulating

valve, then to the water cooled condenser and down

the drain.

Water Level: The correct water level should be

checked when the machine is making ice. Check

the water level in the reservoir and compare it to the

horizontal line molded into the side of the reservoir.

The correct level should be between 1/8” above and

1/4” below the line. If needed, bend the float arm up

or down to adjust the water level.

Water Sensor, now

in water reservoir

Float Valve and

Water Reservoir

Water

Level

Condensate

Pan

Evaporator Water Inlet

Water Schematic