N0922L, N1322L, F1222L, F1522L

Remote Low Side Service Manual Includes Prodigy Plus

December 2014

Page 19

Remote Refrigeration with Condensing Unit

A condensing unit's compressor concentrates the heat

from ice making into high pressure, hot discharge gas.

The high pressure forces the gas to the condenser.

At the remote condenser, the discharge gas will

either enter the coils or bypass them through the

headmaster. The head master maintains a minimum

discharge pressure to keep flash gas out of the liquid

line.

From the condenser, refrigerant flows to the receiver.

It can be either liquid or gas, depending upon the

modulation of the head master.

From the receiver, liquid refrigerant flows to the ice

making head's thermostatic expansion valve. At the

expansion valve, liquid refrigerant passes from a high

pressure zone to one of relatively low pressure, and in

the low pressure zone it evaporates, absorbing heat.

From the evaporator, the refrigerant, carrying the

heat from ice making, flows back to the compressor

through the suction line, and the cycle continues.

When enough ice has been made, the control

system closes the liquid line solenoid valve and the

condensing unit, when used, pumps down, forcing

refrigerant out of the low side until its pump down

pressure switch stops the compressor.

Remote Low Side Refrigeration Schematic

Generic

Condensing

Unit

Liquid

Suction

Ice Making Head

EPR

Liquid Line

Valve

TXV