N0922L, N1322L, F1222L, F1522L

Remote Low Side Service Manual Includes Prodigy Plus

December 2014

Page 25

Service Diagnosis

Symptom

Probable Cause

Possible Correction

No ice

No power

Check that ice machine and

condensing unit, if used, both have

power. If power light is out, check

transformer.

Code 3: No water

Restore water

Status light is off

Push and release ON switch

Code 1: No ice sensed

Check for ice flow down chute. if

very slow or no ice being made,

check water inlet tubing for

restriction; check for condensing

unit or refrigeration system failure
Check auger motor for power, if no

power, check controller component

indicator light. If there is power to

the motor, check motor windings

Code 2: Auger motor draws too

many amps, controller shuts unit

off.

Check that liquid line valve shuts

off tightly
Check for damage to gear reducer

or auger bearings.

Bin Eyes Blocked light is On

Ice is in the chute.
No ice in the chute. Check position

of sensors, check sensors for scale

build up

Everything is in operation, but no

refrigeration effect

Check liquid line valve
Check condensing unit
Check TXV
Check refrigerant charge

Low ice making capacity

Scale build up

Remove scale from evaporator and

water system

Restricted water supply to

evaporator

Squeeze hose, if bubbles appear

revise hose and reservoir

Suction tubing kinked

Check suction tubing

Expansion valve superheat

incorrect

Check superheat