beautypg.com

For the installer, Final check list – Scotsman NME954 User Manual

Page 8

background image

FOR THE INSTALLER

Final Check List

____1. Is the ice system installed indoors in a

location where the air and water
temperatures are controlled, and where
they do not exceed the design limitations?

____2. Is there an electrical service disconnect

within sight of the installed machine? Has
the voltage been checked, and compared
to nameplate requirements?

____3. Have all the plumbing connections been

made and checked for leaks?

____4. Has the machine and bin been leveled?

____5. Is there a minimum of 6" clearance at the

back of the machine for proper service
access and air circulation?

____6. Is the water pressure a minimum of 20

psig?

____7. Has the machine been secured to the bin?

____8. Is there clearance over the top of the

machine for service access?

____9. Is there a water shut off valve installed near

the machine?

____10. Have all of the shipping blocks been

removed?

NME954 & FME1204

May 2001

Page 8