REMOVAL AND REPLACEMENT: Bearing And Breaker

Note: Removal of the auger, water seal, evaporator
and gear motor must begin at the top of the
assembly.
1. Remove panels and disconnect electrical power.

2. Push back bail clamp and remove ice chute
cover.
3. Unscrew and remove ice sweep.
4. Lift up and remove ice chute.
5. The breaker may be removed from the auger
and evaporator without disturbing the auger.

a. Unscrew breaker cover from breaker (left hand

threads)

b. Unscrew auger stud from top of auger.
c. Unscrew 4 allen head cap screws holding

breaker to evaporator.

d. Lift up, and remove breaker/bearing assembly

from auger & evaporator.

6. Service the bearing. Check for rust, rough spots
and damage.

a. The bearing is pressed into the breaker, to

remove the bearing and replace it an arbor press is
needed.

b. Replace lower seals before installing new

bearing in breaker.
Note: seals must be pressed in with a tool pushing
against the outer edge only, they will not install by
hand.
Replace parts as required. Re-grease bearing with
Scotsman part no. A36808-001 bearing grease.
Replace top seal, and check the o-rings, replace if
cut or torn.
7. Reverse to reassemble: specific tools and
materials are required to install properly.
a. Add food grade grease such as Scotsman part
number 19-0569-01 to the seal area before
installing on the auger.
b. Check the seal to shaft areas for cuts, or rough
spots: none are permitted.

NME954 & FME1204

May 2001

Page 25

Note: Flaker parts are shown in this manual.

Nugget Breakers do NOT have a Slotted Collar.

Auger

Stud

Bearing

Seals

Slotted

Collar

Ice

Sweep

Breaker

Cover

Step 5-a

Step 5-b

Step 5-c and Step 6

Electrical shock hazard.
Electrical shock can cause
personal injury.
Disconnect power before
beginning to service
components.