FOR THE PLUMBER

CONFORM TO ALL APPLICABLE CODES

Water Inlet

The recommended water supply is
cold water. Use 3/8" O.D. copper
tubing, connect to the 3/8" male
flare at the back of the cabinet.
Install a hand valve near the
machine to control the water
supply.

Drains

There is one 3/4" FPT drain at the
back of the cabinet, the drain line
is of the gravity type, and 1/4 inch
per foot fall is an acceptable pitch
for the drain tubing. There should
be a vent at the highest point of
the drain line, and the ideal drain
receptacle would be a trapped and
vented floor drain. Use only 3/4"
rigid tubing.
Storage Bin: A separate gravity
type drain needs to be run.
Insulation of this drain line is
recommended.

FLOOR DRAIN

VENT BIN DRAIN

3/4" FPT

VENT

ICEMAKER

DRAIN,

3/4" FPT

WATER INLET

3/8" MALE

FLARE

FIELD

SUPPLIED

WATER FILTER

HAND SHUT

OFF VALVE

CONNECT TO

COLD WATER

FM1200R

November, 1988

Page 9