FOR THE INSTALLER
The FM1200R is designed to fit the following
Scotsman storage bins:
••
B590 and extentions, with bin top KBT18.
••
BH800 using bin top KBT15 (one unit).
••
BH800 if using two units, no bin top needed.
••
BH1000 using bin top KBT16.
••
BH550 or HTB500 using bin top KBT14.
When installing a new system, check to be
sure that you have everything you need
before beginning:
••
Correct Bin
••
Correct Ice Machine
••
Correct Bin Top
••
All kits, legs, and information required for
the specific job.
Back View
Liquid Line
Connnection
Discharge Line
Connection
Remote Condenser
Junction Box
Electrical
Inlet
Water Inlet
3/8" Flare
Drain
3/4" FPT
2.96"
3"
5.25"
20.84"
Allow 6" above
machine for service.
* Minimum Circuit Ampacity is used to determine wire size and type per National Electric Code.
The Standard Finish is Enamel - Sandalwood. There is an optional stainless steel panel kit,
SPKFM21 available to convert the unit to Stainless Steel. It is field installed.
Model Number
FM1200RE-32A
FM1200RE-3A
Dimensions
(w/o bin)
H X W X D
27" x 21" x 24"
same
Basic
Electrical
208-230/60/1
208-230/60/3
Ice Type
FLAKE
same
Cond.
Type
R/Air
R/Air
Min.
Circuit
Ampacity
11.4
10.2
Max
Fuse
Size
20
15
Comp.
H.P.
1.5
1.5
Top View
Allow 6" of space behind the machine
for utility connections.
SPECIFICATIONS: ICEMAKER
FM1200R
November, 1988