COMPONENT DESCRIPTION

Control Box: Contains the electrical controls
that operate the machine.
High Pressure Cut Out: A manual reset
switch sensing the high side refrigeration
pressure. It is set to shut the machine off at
450 psig.
Evaporator: A vertical stainless steel tube,
refrigerated, and water filled. In it, there is a
stainless steel auger.
Reservoir: Float operated, it maintains the
water level in the evaporator at a constant
level, it also contains the water level sensor.
Water Level Sensor: Senses if there is water
in the reservoir to make ice out of. Will shut
the machine off it there is none.

Ice Discharge Chute: Directs the ice
produced by the evaporator into the storage
bin.
Ice Level Sensor: An electronic "eye", it
senses the presence of ice in the bottom of
the ice discharge chute. Operates to turn the
ice machine on and off automatically as the
level of ice in the bin changes.
Gear Motor: An oil filled, speed reduction
gearbox, driving the auger.
Cleaning Drain Tube: When uncapped and
lowered, drains the evaporator.
Compressor: The refrigerant vapor pump.
Expansion valve: The refrigerant metering
device.

CONTROL BOX

EXPANSION VALVE

WATER LEVEL

SENSOR

RESERVOIR

CLEANING

DRAIN TUBE

EVAPORATOR

GEAR MOTOR

ICE LEVEL

SENSOR

HIGH PRESSURE

CUT OUT

COMPRESSOR

ICE CHUTE

FM1200R

November, 1988