OPERATION: Refrigeration

Beginning at the compressor, the refrigerant
502 is compressed into a high temperature
gas. The discharge line directs this gas to the
condenser. At the remote condenser the
gas is cooled by air and it then condenses
into a liquid. This high pressure liquid then
goes through the liquid line to the head
pressure control valve, into the receiver,
through the liquid line valve and then through
the expansion valve. The thermostatic
expansion valve meters liquid refrigerant into
the evaporator, the volume of liquid refrigerant

depending upon the temperature of the
evaporator; warmer evaporators get more
refrigerant and colder evaporators get less. At
the evaporator, the refrigerant enters an area
of relatively low pressure, where it can easily
"boil off" or evaporate. As it evaporates, it
absorbs heat from the evaporator and
whatever is in contact with it (such as the
water inside it). After the evaporator, the
refrigerant, now a low pressure vapor, goes
through the suction line back to compressor,
where the cycle is repeated.

REMOTE CONDENSER

DETAIL OF HEAD

PRESSURE CONTROL

VALVE

EVAPORATOR

DISCHARGE

LINE

LIQUID LINE

HEAD

PRESSURE

CONTROL

VALVE

RECEIVER

COMPRESSOR

Refrigeration Schematic

KING

VALVE

SUCTION

LINE

THERMOSTATIC

EXPANSION

VALVE

LIQUID LINE

VALVE

FM1200R

November, 1988

Page 20