OPERATION: Refrigeration

PUMP DOWN

During the pump down cycle (usually initiated
by the circuit board de-energizing the liquid
line valve) the discharge gases flow through
their normal path to the remote condenser,
through the head pressure control, and into
the receiver. At this point the refrigerant flow

is stopped by the closed liquid line valve. This
action forces the refrigerant into the receiver
and keeps it out of the compressor. The
pump down continues until the low pressure
control turns the compressor off.

REMOTE CONDENSER

EVAPORATOR

DISCHARGE

LINE

LIQUID LINE

HEAD

PRESSURE

CONTROL

VALVE

RECEIVER

COMPRESSOR

Refrigeration Schematic

KING

VALVE

SUCTION

LINE

THERMOSTATIC

EXPANSION

VALVE

LIQUID LINE

VALVE

FM1200R