beautypg.com

Fm1200r, Maintenance and cleaning – Scotsman FM1200R User Manual

Page 24

background image

/////////////////////////////WARNING///////////////////////////
Disconnect electrical power before beginning.
//////////////////////////////////////////////////////////////////////////
1. The bin control uses devices that sense
light, therefore they must be kept clean
enough so that they can “see”. At least twice a
year, remove the bin control sensors from the
base of the ice chute, and wipe the inside
clean, as illustrated.
2. The ice machine senses water level by a

probe located in the water reservoir. At least
twice a year, the probe should be removed
from the reservoir, and the tip wiped clean of
mineral buildup.
3. The top bearing in the breaker should also
be checked at least two times per year.
Check the breaker bearing by:

••

removing the ice chute cover

••

unscrewing the ice sweep

••

removing the water shed

••

using a spanner wrench and unscrewing
the breaker cover (left hand thread)

••

unscrewing the auger stud

Inspect the assembly, looking for wear
4. Clean the remote condenser. Use a
vacuum cleaner or coil cleaner if needed.
Do NOT use a wire brush.
5. Check and tighten all bolts and screws.

MAINTENANCE AND CLEANING

RESERVOIR

WATER LEVEL

SENSOR

SLIDE UP

TO REMOVE

//////////////////////////////////////

CAUTION: THE TIP

IS MADE OF GLASS

///////////////////////////////////////

ICE CHUTE

ICE LEVEL

SENSORS

SLIDE LEFT TO

REMOVE

ICE

SWEEP

SPANNER

WRENCH

BREAKER

COVER

FM1200R

November, 1988

Page 24