beautypg.com

Cse60, How it works, Component description – Scotsman CSE60 User Manual

Page 7

background image

CSE60

June 2001

Page 7

HOW IT WORKS:

COMPONENT DESCRIPTION

Cube Size Control
The cube size control is located in front of the

control box, behind the front panel. The sensing

capillary tube of the cube size control is routed

out of the control box into its bulb holder on the

evaporator coil. It is a reverse acting

temperature control with double throw contacts.

Turning its knob all the way counterclockwise

also shuts off the ice maker.
The control determines the length of the freezing

cycle and correspondingly the size of the cube.

A lower setting will produce a smaller cube, and

a higher setting will make a larger cube. The

cube size control changes its contacts when the

evaporator reaches its preset temperature,

starting the harvest cycle. When the sensing

tube of the cube size control reaches the high

preset temperature, the contacts change again,

restarting the freeze cycle.
Compressor Toggle Switch.
The compressor toggle switch is located on the

side of the control box. When moved to the ON

position, it makes a circuit to the compressor.

When moved to the OFF position, the other

components will still operate.
High Temperature Cut Out
This control senses the temperature of the

discharge line and will open to stop the

operation of the ice machine should the

discharge temperature exceed the preset

maximum (175

o

F). After it cools to 140

o

F. it must

then be manually reset to restart the machine by

pushing the button at the front of the control box.
Water Pump
The water pump operates during the freezing

cycle only, pumping water through the spray

nozzles into the inverted spray cups.
Inlet Water Solenoid Valve
The water solenoid valve, located in the back

panel of the unit, is energized only during the

harvest or cleaning cycles. When energized it

allows a metered amount of water to flow into

the machine (.21 g.p.m.) This water flows to the

top of the evaporator and then down into the

reservoir.

Bin Thermostat Control
The bin thermostat control body is located in

front of the control box just beside the cube

size control. The thermostat sensing tube is

located in the ice storage bin on the left side wall

where is automatically shuts the ice maker off

when the bin is full and restarts when ice is

removed. Factory settings are 1 degree C (36

degrees F) cut out and 4 degrees C (39 degrees

F) cut in. It can be adjusted by turning the

adjustment screw visible through the control box

cover.
Hot Gas Valve Assembly
The hot gas valve assembly is comprised of two

parts, the valve body and the coil. These parts

are located on the discharge line of the

compressor and are activated by the cube size

control (harvest cycle). When the coil of the hot

gas valve is energized, it magnetically lifts the

plunger in the hot gas valve body. This allows

hot refrigerant gas to by-pass the condenser and

go directly to the evaporator.
Spray Platform and Chute
The spray system used on this unit is of the

stationary type. The water is forced by the

water pump into the platform chamber and

sprayed into the inverted cup molds through a

set of six spray nozzles.
Fan Motor
The fan motor is electrically connected through

the cube size control and runs only during the

freezing cycle.
Hermetic Motor Compressor
The compressor is a vapor pump, forcing

refrigerant gas throughout the refrigeration

system.