Cse60, Service diagnosis – Scotsman CSE60 User Manual

Page 15

background image

CSE60

June 2001

Page 15

SYMPTOM

POSSIBLE CAUSE

SUGGESTED CORRECTION

Unit will not run

Blown fuse or breaker

Replace fuse & check for

cause of blown fuse, reset

breaker.

Compressor cycles

intermittently

Low voltage

Check voltage at the supply to

the building.
Check circuit for overloading.

Dirty condenser

Clean the condenser

Air circulation blocked around

unit

Allow sufficient air around unit

Non condensable gas in

system

Evacuate and recharge with

nameplate charge

Cubes too small

Cube size control set too

warm

Check and adjust for proper

operation

Partially restricted cap tube

Blow charge, evacuate with

new drier, weigh in nameplate

charge

Moisture in system

Same as above

Overcharged

Same as above

Undercharged

Same as above, look for a

leak.

Cloudy cubes

Spray nozzles plugged

Clean

Needs cleaning

Clean with Scotsman Ice

Machine Cleaner

Irregular size cubes, some

cloudy

Some jets plugged

Clean jets

Shortage of water

Check water supply

Cubes too large

Cube size control set

improperly

Check and adjust for proper

operation

Decreased ice capacity

Inefficient compressor

Replace

SERVICE DIAGNOSIS