EVAPORATOR

ACCUMULATOR

CAPILLARY TUBE

COMPRESSOR

STRAINER

CONDENSER

FILTER-DRIER

DISCHARGE LINE

LIQUID

LINE

SUCTION

LINE

HOT GAS

SOLENOID

(OPEN)

HOW IT WORKS:

REFRIGERATION

HARVEST CYCLE

(When the cubes are released)

The ice cubes have been formed in an inverted

mold that was refrigerated.
Now the refrigeration system will change to

warm the cube mold and release the cubes.
The process begins at the compressor. There,

refrigerant vapor is compressed and flows from

the compressor through the discharge line as a

high temperature, high pressure gas. Before the

gas gets to the condenser,it goes through a

strainer, the strainer outlet is connected to two

tubes, one of which leads to an electric valve,

the hot gas solenoid. When this valve opens,

the refrigerant gas follows the path of least

resistance and flows through the tubing from the

hot gas valve to the evaporator, where the ice

cubes are frozen.
At the evaporator, the high temperature gases

are cooled by the cold temperatures of the cube

mold, and condense into liquid, transferring heat

to the mold which warms up and releases the

cubes.
The refrigerant, now a low pressure, low

temperature vapor, flows into the accumulator,

which traps excess liquid refrigerant. The vapor,

now primarily a gas, goes through the suction

line tube to the compressor where the cycle is

repeated.