ADJUSTMENT OF THE BIN THERMOSTAT

CONTROL
Adjust the bin thermostat when the ice maker

turns off too soon (ice level low) or when it turns

off too late (ice storage bin overfills.)
To increase the ice level in the storage bin:

·

Rotate the bin thermostat adjustment screw

(located under front panel on control box

cover) clockwise one eight turn at a time until

the ice level that the machine maintains is

correct.

To decrease the ice level in the storage bin:

·

Rotate the bin thermostat adjustment screw

counterclockwise one eight turn at a time until

the ice level is correct.

CORRECT SIZE

TOO SMALL, LITTLE OR NO

ICE IN THE CENTER OF THE

CUBE.

TOO BIG, THICK BULGE OF

SOLID ICE ON THE END.

ADJUSTMENT OF THE CUBE SIZE:
Adjust only when cubes are too big or small.
(See the illustration at the right.)
1. Remove front panel, locate knob.
2. To increase the size, turn knob 1/8 turn

clockwise. To make the cubes smaller, turn the

knob 1/8 turn counterclockwise.
3. Observe the size of the cubes in the next two

harvest cycles, if more adjustment is needed,

continue adjustments until the correct size is

obtained.

OPERATION & ADJUSTMENT: OPERATING CHARACTERISTICS

The information shown below covers a wide range of air and water temperatures. It is intended as a

guideline only, and is based on data compiled from NEW CLEAN units. Allow a variation from each

end of the range given.
A. Refrigeration system pressures:

High Side (discharge)

End of Freeze cycle 125 - 130 psig
Harvest cycle 83 - 125 psig

Low side (suction)

End of Freeze cycle 1 - 3 psig
Harvest cycle (maximum) 120 psig

B. Freeze cycle time 20 - 25 minutes
C. Defrost cycle time 2 - 3 minutes
D. Compressor amps

Freeze cycle 4.3 to 3.6
Harvest cycle 3.6 to 7.7