ADJUSTMENT OF THE BIN THERMOSTAT
CONTROL
Adjust the bin thermostat when the ice maker
turns off too soon (ice level low) or when it turns
off too late (ice storage bin overfills.)
To increase the ice level in the storage bin:
·
Rotate the bin thermostat adjustment screw
(located under front panel on control box
cover) clockwise one eight turn at a time until
the ice level that the machine maintains is
correct.
To decrease the ice level in the storage bin:
·
Rotate the bin thermostat adjustment screw
counterclockwise one eight turn at a time until
the ice level is correct.
CORRECT SIZE
TOO SMALL, LITTLE OR NO
ICE IN THE CENTER OF THE
CUBE.
TOO BIG, THICK BULGE OF
SOLID ICE ON THE END.
ADJUSTMENT OF THE CUBE SIZE:
Adjust only when cubes are too big or small.
(See the illustration at the right.)
1. Remove front panel, locate knob.
2. To increase the size, turn knob 1/8 turn
clockwise. To make the cubes smaller, turn the
knob 1/8 turn counterclockwise.
3. Observe the size of the cubes in the next two
harvest cycles, if more adjustment is needed,
continue adjustments until the correct size is
obtained.
OPERATION & ADJUSTMENT: OPERATING CHARACTERISTICS
The information shown below covers a wide range of air and water temperatures. It is intended as a
guideline only, and is based on data compiled from NEW CLEAN units. Allow a variation from each
end of the range given.
A. Refrigeration system pressures:
High Side (discharge)
End of Freeze cycle 125 - 130 psig
Harvest cycle 83 - 125 psig
Low side (suction)
End of Freeze cycle 1 - 3 psig
Harvest cycle (maximum) 120 psig
B. Freeze cycle time 20 - 25 minutes
C. Defrost cycle time 2 - 3 minutes
D. Compressor amps
Freeze cycle 4.3 to 3.6
Harvest cycle 3.6 to 7.7