ELECTRICAL CONNECTIONS: KCMR230 Kit
When 2 ice machines are connected to 1 remote
condenser and the fan motor is powered from the
ice machines, a relay kit is required to maintain
power to the fan motor.
All external wiring should confrom to the national,
state and local codes.
1. Attach the control box of the KCMR230 to a
permanent location that is convenient for each ice
machine’s connection and for future service.
Attach a solid earth ground wire to the Ground
Screw.
2. Route connecting wires from the first ice
machine’s fan junction box and connect to the
relay kit terminal strip marked: No. 1 Ice Machine.
3. Route connecting wires from the second ice
machine’s fan junction box and connect to the
relay kit terminal strip marked: No. 2 Ice Machine.
4. Attach wires at the KCMR230 terminal strip
marked: To Remote Fan, and route them to the
remote condenser junction box.
5. Make the proper electrical connection at the
junction box.
Conform To All Applicable Codes
Remote Condenser
Junction Box
Possible Location
for KCMR230
Fan Juntion Boxes
KCMR230 Installation
CME650R
March 1994