beautypg.com

For the installer, Cme650r – Scotsman CME650R User Manual

Page 2

background image

Model Number

Dimensions
(without bin)
W" x D" x H"

Basic
Electrical

Minimum
Circuit
Ampacity*

Maximum Fuse
(or HACR Circuit
Breakers) Size

Refrigerant
Charge**
HP62 (R-404a)

Condenser
Type

CME650RE-32A 30 X 24 X 27

208-230/60/1 16.9

20

208 oz.

Remote Air

CME650RE-3A

30 X 24 X 27

208-230/60/3 5.9

15

208 oz

Remote Air

* Minimum Circuit Ampacity is used to determine wire size and type per the National Electric Code.

** The unit is shipped with the full charge in the receiver. For re-charging purposes, if the nameplate charge
is different than this number, go by the nameplate.

Use Scotsman remote condenser RCE651-32A, RCE652-32A or ERC201-32A or ERC402-32A. Use
precharged tubing kit RTE25 (25’) or RTE40 (40"). Fan relay kit KCMR230 required when two ice machines
are powering 1 remote condenser.

This ice system (except remote condenser) is designed to be installed indoors, in a controlled environment.

MINIMUM

MAXIMUM

Air Temperature

50

0

F.

100

0

F.

Water Temperature

40

0

F.

100

0

F.

Water Pressure

20 psi

80 psi

Voltage

-10%

+10%

Scotsman Ice Systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of U.L., N.S.F., and C.S.A.

Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any parts and/or other components not
specifically approved by Scotsman.

Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and designs are subject to change
without notice.

FOR THE INSTALLER

The CME650R will fit the following Scotsman ice
storage bins:

••

*BH550

••

*HTB500, HTB350, HTB250

••

BH800 (with bin top KBT23)

••

BH900 (with bin top KTB22)

••

BH1360

It will also fit these Scotsman Dispensers:

••

CD200

••

IS150 (with adapter kit KADCM1)

••

RS150 (with adapter kit KADCM1)

*These smaller bins are recommended.

A remote condenser and precharged tubing kit are
required to assemble this ice system.

The normal finish for the machine is enamel. An
optional stainless steel panel kit (SPKCMD-1) can
be field installed. It contains a stainless steel top,
side panels, service panels, and front panel.

CME650R

December 1995

Page 2