SERVICE DIAGNOSIS: Water

SYMPTOM

POSSIBLE CAUSE

PROBABLE FIX

No ice is made

Inlet water valve will not open or
is dirty

Clean inlet screen, check coil,
replace valve if required

No water being pumped over
evaporators.

Check pump motor, replace pump
if motor will not run.

No water in reservoir, check inlet
water valve, check reservoir for
leak.

Water inlet valve leaks thru at
high rate

Replace inlet water valve

Cubes are not uniform in shape

Water distributors are dirty

Clean water system

Long Freeze Cycle

Inlet water valve leaks through

Replace inlet water valve

See electrical/adjustment

See electrical/adjustment

Makes thick ice/freezes up

Water inlet valve restricted

Clean or replace valve

Low water pressure

Check water filter or supply

Cubes too large

Inlet water valve leaks through

Replace inlet water valve

See electrical/adjustment

See electrical/adjustment

Low Capacity

Incoming water very warm

Check water temperature to
building

Lack of water

See unit runs out of water

Unit runs out of water

Reservoir leaks

Repair leak

Inlet water valve restricted

Clean or replace valve

Short harvest cycle

Adjust timer

Water pressure too low

Check supply

CME650R

October 1994

Page 23