Water Pump

1. Remove front panel.

2. Unplug water pump electrical connection.

3. Drain water reservoir.

4. Use corbin clamp pliers to loosen and slide
corbin clamps on hoses away from pump.

5. Remove screws retaining pump to bracket.

6. Pull pump out of ice machine.

7. Reverse to reassemble.

8. Replace front panel.

8. Reconnect electrical power.

Inlet Water Solenoid Valve Assembly

To remove the inlet water solenoid valve assembly:

1. Shut OFF water supply to machine.

2. Loosen and remove outlet water line from the
inlet water solenoid valve assembly.

3. Remove screws and pull the water solenoid

valve out to gain access.

4. Pull electrical cord from solenoid coil terminals.

5. Remove inlet water fitting from the water
solenoid valve. To replace the inlet water valve
assembly, reverse the removal procedures.

6. Reverse to reassemble.

Electrical Shock
Hazard.
Electrical shock can
cause personal injury.
Disconnect power
before beginning to
service components.

REMOVAL AND REPLACEMENT

INLET WATER

VALVE

REMOVAL OF THE

INLET WATER VALVE

Removal of The

Water Pump

Inlet Water

Valve Screen,

May Be

Cleaned As

Needed

CME650R

October 1994

Page 27