Appendix d (quiet zone analysis), Std i2of5 warning qz/ss – RJS Inspector D4000 SP (FIRMWARE version A.06 and Later) User Manual
Page 45
Operator
’s Guide
Appendix D
002-5572
RJS, Minneapolis, MN
37
Appendix D (Quiet Zone Analysis)
Quiet Zone Analysis
The RJS Inspector D4000 trims data gathered during a
scan to approximately 10 times the X dimension on
each side of a bar code for all symbologies except
UPC and EAN. The areas are assumed to be quiet
zones and are included in the symbol analysis. If a low
reflectance object is detected in these areas the
screen displays:
Std I2of5
Warning QZ/SS
Quiet Zone Analysis for UPC and EAN symbols are
described in the following tables. In cases where an
addendum is included in the bar code, an addendum
gap analysis is also performed.
Table D-1 (Acceptable Parameters for Symbols
Without Addendums)
Symbology
Leading QZ
Trailing QZ
UPC-A
9X Minimum
9X Minimum
UPC-E
9X Minimum
7X Minimum
EAN-13
11X Minimum
7X Minimum
EAN-8
7X Minimum
7X Minimum
Table D-2 (Acceptable Parameters for Symbols With
Addendums)
Symbology
Leading QZ
Trailing QZ
GAP Size
UPC-A
9X Minimum
5X Minimum
9 - 12X
UPC-3
9X Minimum
5X Minimum
9 - 12X
EAN-13
11X Minimum
5X Minimum
7 - 10X
EAN-8
7X Minimum
5X Minimum
7 - 10X