beautypg.com

0 pass/fail analysis screen – RJS Inspector D4000 SP (FIRMWARE version A.06 and Later) User Manual

Page 27

background image

Operator

’s Guide

Inspector D4000

™ Laser SP

002-5572

RJS, Minneapolis, MN

19

7.0 Pass/Fail Analysis Screen

After the symbol is scanned the Pass/Fail Analysis
Screen
will be displayed.

An example of a Pass/Fail Analysis Screen for an
acceptable symbol is shown below:

*1234ABCD*
Code 3of9
D/bility % .64
D/bility Grade A


This screen shows:

The first line is the decoded data. (If more than 16

characters are present, those characters will wrap
to the next row of the display) Press

Select

to

scroll through the data

The second line provides the Symbology type

The third line is the ISO/ANSI Decodability per-

centage grade

The fourth line is the ISO/ANSI Decodability letter

grade


Below is a sample of scans remaining in multiple scan
mode if the last scan has not been completed.

*1234ABCD*
02 Scans Remain.


If the symbology code is 128, only printable characters
will be displayed.

Note:

See Appendix E for descriptions of how these codes
are displayed