Jumper Settings for ELECTH-HPUMP and HE-HG:

Mounting:
1. Open the ZTS-100 by pushing the hook (Figure 5)
2. Install AAx4pcs batteries if using battery power (Alkaline batteries are

recommended)

3. Check the polarity of the batteries and the "+/-" marks inside the battery

compartment

4. Connect 24Vac power if using 24Vac power source
5. Place the cables at the hole near the terminal block
6. Insert 2 pieces of wall anchors into the holes of the wall
7. Fasten the thermostat with 2 pieces of long screws through the 2 mounting holes

(Figure 6)

8. Install the top housing by hooking the bottom (Figure 6)

Jumper Function Description

Set to ELECTH for non heat pump system (

Default)

Set to HPUMP for heat pump system

Set to HG for Gas heat-fan controlled unit (

Default)

Set to HE for Electrical heat-fan controlled unit

ELECTH

HPUMP

ELECTH

HPUMP

HG

HE

HG

HE

Figure 6. Install the top housing

Figure 5. Open ZTS-100