beautypg.com

Limited at "heat set point" + 4 f: 74 f, 76 f automatically to maintain the dead band – Remotec ZTS-100 V2.04 User Manual

Page 29

background image

COOL Mode: thermostat controls the temperature according to the following diagram

o

o

Example for Cooling: (Set point = 80 F, Swing = 1 F)

o

o

=> Cooler turns on when room temp is 81 F and off at 79 F.

AUTO: thermostat controls the temperature according to the following diagram

o

o

There is a dead band 4 F/2 C between heat set point and cool set point.

Example 1: If user select heat set point is 70F, the minimum cool set point will be

o

o

limited at "heat set point" + 4 F: 74 F

o

o

Pervious heat set point is 70 F and cool set point is 74 F

o

Example 2: If user changes heat set point to 72 F, cool set point will be updated to

o

76 F automatically to maintain the dead band.

Swing

Temperature

Output

Off

Cool

Turn off

Set point

Turn on

Temperature

Output

Off

Heat

st

1 Turn off

nd

2 Turn off

Heat Set point

st

1 Turn on

nd

2 Turn on

Diff

Swing

Swing

Dead band

Cool Set point

28