Support association command class, Lcd indication step procedure / description – Remotec ZTS-100 V2.04 User Manual
Page 22

Delete (Exclusion) ZTS-100 from Gateway / Controller Z-Wave network
Support Association Command Class
ZTS-100 support 2 association groups, each association group contains 5 nodes
max. and up to 5 nodes can be assigned in these 2 association groups.
Association group_1:
- ZTS-100 will send out basic set command 0xFF automatically once Heat Pump
operation has been started in heating mode.
- ZTS-100 will send out basic set command 0x00 automatically once Heat Pump
operation has been stopped in heating mode.
Association group_2:
- ZTS-100 will send out basic set command 0xFF automatically once Compressor
operation has been started in cooling mode.
- ZTS-100 will send out basic set command 0x00 automatically once compressor
operation has been stopped in cooling mode.
If the ZTS-100 is removed from the
network, it shows no connection.
Exclusion is completed.
3
Press "Home" key once to go back to the
home page.
4
WAKE
AM
PROG ON
MO
FAN AUTO
OFF
21
LCD indication
Step
Procedure / Description
Gateway / Controller device should entry
the Exclusion mode.
Press and hold "Home" key for 2 seconds
to entry the Add (Inclusion) / Delete
(Exclusion) Mode.
1
Press "Prog" key once, it will search the
network.