beautypg.com

Lcd indication step procedure / description, Defrost icon will be displayed at home – Remotec ZTS-100 V2.04 User Manual

Page 26

background image

Defrost Indication

Out of Temperature Range Indication

Energy Saving Mode

LCD indication

Step

Procedure / Description

DEFROST icon will be displayed at Home

o

o

page if temperature below 41 F/5 C.

All heaters will be forced On, except in
cool mode.

1

WAKE

DEFROST

AM

TU

HEAT

FAN AUTO

1

2

PUMP

LCD indication

Step

Procedure / Description

HI icon will be displayed on LCD if
temperature excess the measurement

o

o

ranges 99 F/40 C.

All heaters will be forced Off.
Cooler will turn on if running cool mode.

1

WAKE

AM

TU

FAN AUTO

1

COOL

LO icon will be displayed on LCD if
temperature below the measurement

o

o

ranges 32 F/0 C.
All heaters will be forced On, except in
cool mode.

2

WAKE

DEFROST

AM

TU

HEAT

FAN AUTO

1

2

PUMP

LCD indication

Step

Procedure / Description

User can enable/disable energy saving
mode by using Z-Wave BASIC set
command only.

=> Enable energy saving mode
Basic set value = 0x00 (off mode)
(energy saving mode will be mapped to
off mode)

=> Disable energy saving mode
Basic set value = 0xFF (resume mode)
(comfort mode will mapped to resume
mode)

1

25