beautypg.com

Z-wave configuration command, Parameter value range parameter number definitions, Celsius ( c) – Remotec ZTS-100 V2.04 User Manual

Page 23: A = (b+2)min. ~ (37.0 c) max, Fahrenheit ( f), A = (b+4)min. ~ (99.0 f) max, 0x00 = c

background image

Z-Wave Configuration Command

Parameter value range

Parameter Number

Definitions

o

o

0x01 = 0.5 C / 1 F

o

o

0x02 = 1.0 C / 2 F

(default)

o

o

0x03 = 1.5 C / 3 F

o

o

0x04 = 2.0 C / 4 F

1 (0x01)

Swing

o

o

0x01 = 0.5 C / 1 F

o

o

0x02 = 1.0 C / 2 F

(default)

o

o

0x03 = 1.5 C / 3 F

o

o

0x04 = 2.0 C / 4 F

2 (0x02)

Differential

0x01F4 to 0x0FA0

(default = 0x01F4,

resolution = 0x0064)
(500 to 4000 hours;
resolution=100hrs )

3 (0x03)

Set filter counter

0x0000 to 0x270F
(0 to 9999 hours)

4 (0x04)

Report filter counter

(read only)

(A) available range:

o

Celsius ( C):

o

A = (B+2)min. ~ (37.0 C) max.

o

Fahrenheit ( F):

o

A = (B+4)min. ~ (99.0 F) max.

o

(default = 99.0 F)

6 (0x06)

Upper limit of set point (A)

o

0x00 = C

o

0x01 = F

(default)

5 (0x05)

Scale of temperature

(B) available range:

o

o

o

Celsius ( C): 5.0 C to 35.0 C

o

o

o

Fahrenheit ( F): 41.0 F to 95.0 F

o

(default = 41.0 F)

7 (0x07)

Lower limit of set point (B)

0x00 = Disable (Normal mode)
0x01 = Enable (Simple mode),

default

8 (0x08)

Simple mode

0x00 = 24 hours
0x01 = 12 hours (am / pm),

default

9 (0x09)

Time format

22

Value(X): 0x00, 0x03 to 0xFF
0X00 = Disable,

default

Range from 0x03 to 0xFF =
3 minutes to 255 minutes
(Thermostat sends "Basic Set"
command to its association node
repeatedly in every X minutes)

10 (0x0A)

Repeat basic set counter