Remko smart wp-manager – REMKO WPM-Smart-Control-Manual for users-WKF-180 User Manual

Page 14

background image

Favourites menu: for the user

Using the rotary knob (turning it clockwise) you can

access other views. They allow you to rapidly and

easily adjust the most important parameters and

view the yield in kilowatt hours and weather infor-

mation.

Hot water

The Storage tank set temperature (set with the

left softkey, then confirm with "OK") is the tempera-

ture to which conventional reheating should heat

the storage tank to ensure comfortable conditions.

If there is a solar yield, the storage tank can

become substantially warmer. The maximum tem-

perature for solar charging can be modified under

Settings/Solar/Storage tank. For efficiency rea-

sons, the lowest possible set temperature should

be selected. If the available quantity of hot water is

insufficient, the value should be increased. Pay

attention to the maximum temperature of the heat

generator while doing so.

The Mode (select with the right softkey, then con-

firm with "OK") for hot water preparation can be set

as follows:

Automatic comfort: Hot water preparation always

takes place according to the setpoint, i.e. no opti-

misation of the solar yields.

Automatic eco: In order to optimise the solar yields,

during solar storage tank charging, the set temper-

ature of the storage tank is reduced by the "Toler-

ance during solar operation". This delays the

reheating of the storage tank or, where the solar

output is sufficient, prevents it.

Solar only: The hot water is heated exclusively by

solar, i.e. if the temperature drops below the set

temperature, no conventional reheating takes

place.

Fig. 20: Hot water

Then turn the rotary knob clockwise.

Room climate

Colder/Warmer can be used to adjust the temper-

ature of the heating (set with the left softkey, then

confirm with "OK"). If the room temperature is too

low, the room thermostat (on the heater) should

first be set higher. If this is not sufficient, then set

the Warmer/Colder value higher by 1°C. This also

roughly corresponds to one degree of room tem-

perature.

Room climate mode (select the right softkey, then

confirm with "OK") allows you to define the oper-

ating status of the room heater.

Automatic (recommended): the mode switches

automatically between heating, standby and

cooling (special equipment), based on the outside

temperature. This takes account of the ability of

the building to retain heat. For example, on cooler

summer nights the room heater stays off, pre-

venting unnecessary operation.

Heating: heating mode occurs in accordance with

the outside temperature and the heating curve

(weather-controlled).

Standby: in standby mode neither heating nor

cooling occurs, however anti-freeze protection is

active.

Cooling: cooling mode occurs in accordance with

the outside temperature and the cooling curve

(weather-controlled).

Fig. 21: Room climate

Then turn the rotary knob clockwise.

REMKO Smart WP-MANAGER

14