Remko rvd...dc, Technical data – REMKO RVD 351 DC User Manual
Page 30

Technical data
Range
RVD 351DC
RVD 521DC
Operational mode
Cooling / heating
Nominal cooling output
1)
kW
3.52 (1.41 to 4.11)
5.27 (1.59 to 5.65)
Nominal heating output
2)
kW
4.29 (1.43 to 4.83)
5.86 (1.45 to 6.15)
Energy efficiency class, cooling
1)
A
A
Energy efficiency ratio EER
1)
3,32
3,25
Energy efficiency class, heating
2)
A
A
Coefficient of performance COP
2)
3,61
3,80
Power consumption, annual, (500h) C/H
410 / 560
810 / 770
Operating range (room volume), approx.
m³
110
160
Coolant
410A
4)
Power supply
V / Hz
230/1~/50 Hz
Nom. electrical power consumption, cooling
1)
kW
1,06 (0,41-1,45)
1,62(0,56-2,63)
Nom. electrical power consumption, heating
2)
kW
1,19 (0,38-1,88)
1,54 (0,72-2,65)
Electr. rated power consumption
kW
1,90
2,60
Electr. nominal power consumption cooling
1)
A
4,34 (2,02-12,24)
7,08 (2,43-12,35)
Electr. nominal power consumption heating
2)
A
6,64(2,06-12,03)
6,82 (3,13-12,32)
Electr. starting current, max.
A
12,0
12,0
Coolant connection - injection line
Inches
(mm)
1/4 (6,35)
1/4 (6,35)
Coolant connection - suction line
Inches
(mm)
1/2 (12,70)
1/2 (12,70)
Max. operating pressure
kPa
4200
Corresponding
indoor unit
RVD 351DC IT
RVD 521DC IT
Adjustment range, room temperature
°C
+17-+30
Operating range
°C
+17-+31
Air flow volume per speed setting
m³/h
510/530/680
560/710/800
Sound pressure level per speed setting
3)
dB(A)
33/37/40
37/40/42
Protection degree
IP
X0
Condensate drain
mm
25
Condensate pump, flow rate, max.
mmWS
500
750
Dimensions - height
mm
255
Width
mm
580
Depth
mm
580
Dimensions Cover length / width
mm
650 / 650
Weight
kg
21,0
Corresponding
outdoor component
RVD 351DC AT
RVD 521DC AT
Operating range - cooling
°C
+5 - +43
+5 - +43
Operating range - heating
°C
-5 - +24
-5 - +24
Air flow rate, max.
m³/h
2400
Protection degree
IP
24
Noise output max.
3)
dB(A)
48
52
Refrigerant, basic quantity
kg
1,40
1,70
Refrigerant, additional quantity > 5 m
g/m
30
30
Refrigerant pipe, max. length
m
15
20
Refrigerant pipe, height indoor unit and out-
door unit max.
m
10
10
Dimensions - height
mm
590
700
Width
mm
760
845
Depth
mm
280
310
Weight
kg
41,0
63,0
Serial number
548...
549...
EDP no.
1623160
1623170
1) Air intake temp. TK 27°C / FK 19°C, outdoor temp. TK 35°C / FK 24°C, max. air volume, 5m pipe length in combination with MVT 900 / 950 DC
2) Air intake temperature TK 20°C outdoor temperature TK 7°C, FK 6°C, max. air volume, 5m pipe length in combination with MVT 900 / 950 DC
3) Gap 1 m free space 4) Contains greenhouse gas according to Kyoto protocol
REMKO RVD...DC
30