Air filter for indoor unit

Clean the air filter at intervals of
no more than 2 weeks.
Reduce this interval in case of
heavily soiled air.

Cleaning the cover
of the indoor unit

1. Disconnect the supply voltage

to the equipment.

2. Open and fold down the air

inlet guard on the cover. The
filter is held in place by the flaps
screwed in at the side of the
guard (Fig. 1).

3. Clean the guard using a soft,

damp cloth.

4. Switch the supply voltage back

on.

Cleaning the filter

1. Disconnect the supply voltage

to the equipment.

2. Open and fold down the air

inlet guard on the cover. The
filter is held in place by the flaps
screwed in at the side of the
guard (Fig. 1).

3. Tilt the filter and lift it out.

4. Clean the filter using a normal

vacuum cleaner (Fig. 2).
Turn the dirty side until it faces
up.

5. Any dirt can be cleaned off us-

ing lukewarm water and mild
cleaning agents.
To do so, turn the dirty side
downward (Fig. 3).

6. When using water, allow

the filter dry out properly in air
before replacing it in the unit.

7. Carefully insert the filter. Make

sure it is seated correctly.

8. Close the cover as described

above but in reverse order.

9. Switch the supply voltage back

on.

10. Switch the unit back on.

Cleaning the
condensation pump

The indoor unit includes a built-in
condensation pump,
for pumping the condensation to a
drain at a higher level.

The pump is more or less main-
tenance free. The condensation
pipes should be checked for dirt
at regular intervals. Clean them as
required.

If an external pump is also used,
observe the maintenance and care
instructions given in the separate
operating manual.

1 Guard on cover

2 Clean with a vacuum cleaner

3 Cleaning with lukewarm water