Remko rvd...dc, Heating- mode heating mode operational sequence, Functional diagram – REMKO RVD 351 DC User Manual
Page 10

HEATING-
MODE
Heating mode operational sequence
> 6 Min.
> 3 Min.
> 6 Min.
30 sec.
30 sec.
Nominal temperature +5 ℃
Nominal temperature +2 ℃
Fan operation IT
Fan operation AT
Compressor operation AT
Actual temperature
Stop heating
operation
Heating mode
Start heating
mode
Functional diagram
Operation
Stop
Reverse flow valve
30 sec.
30 sec.
During the defrosting cycle, the indoor unit vaporiser fan and the out-
door unit liquefier fan are switched off.
After the cycle is concluded, the fans are switched to their
previous settings.
< 7 Min.
Defrost period
15 sec.
60 sec.
Fan operation IT
Fan operation AT
Compressor operation AT
Operation
Stop
Reverse flow valve
30 sec.
30 sec.
30 sec.
3 Min.
▲
▼
AND
MODE
In the heating mode, you can heat the room in spring or fall. The desired
room temperature is set with the
▲/▼ buttons in 1 °C increments. If the
room temperature is 1 °C below the selected target temperature, the in-
door unit starts to heat the air in the room. The inverter controller checks
the difference between the adjusted target temperature and the actual
room temperature.
In the event of a greater difference, a higher cooling performance is created.
In the event of a smaller difference, a lower cooling performance is created.
This serves to maintain the air discharge temperature and the room tempera-
ture.
If the adjusted room temperature is still exceeded by approx. 2 °C, then
the control system turns the heating function off. To protect the com-
pressor, the regulation only turns the heater on again after a waiting
period of 3 minutes.
In heating mode, the indoor unit fan motor is switched on after a delay,
in order to prevent the discharge of cold air.
The fins on the outdoor unit could crack at low outdoor temperatures.
Regular reversal of the cooling circuit results in a defrosting action. The
display shows "H1" during the defrosting period.
HEATING Mode
FAN
20
10:49
TEMP
CLOCK
SPEED
HEAT
LOW
°
C
2i
10:49
TEMP
CLOCK
SPEED
DRY
AUTO
°
C
2i
10:49
TEMP
CLOCK
SPEED
HEAT
LOW
°
C
23
10:49
TEMP
CLOCK
SPEED
HEAT
LOW
°
C
23
10:49
TEMP
CLOCK
SPEED
HEAT
MED
°
C
REMKO RVD...DC
10