REMKO ML 263 DC User Manual
Page 9
Data specific to outdoor unit
ML 263 DC AT
ML 353 DC AT
ML 523 DC AT
Power supply
V/Ph/
Hz
230 / 1~ / 50
Operating range, cooling
°C
+5 to +50
Operating range, heating
°C
+5 to +30
7)
Air flow rate, max.
m³/h
1800
1800
2200
Enclosure class
IP
24
Sound power level max.
dB (A)
64
64
62
Sound pressure level
5)
dB (A)
56
56
54
Refrigerant
6)
R 410A
Refrigerant, basic capacity
kg
0.80
0.80
1.25
Max. operating pressure
kPa
4200 / 1500
Refrigerant, additional quantity >5m
g/m
20
Refrigerant piping, max. length
m
25
25
30
Refrigerant piping, max. height
m
10
10
15
Refrigerant connection
Liquid line
Inche
s
(mm)
1/4 (6.35)
1/4 (6.35)
1/4 (6.35)
Refrigerant connection
Suction pipe
Inche
s
(mm)
3/8 (9.52)
3/8 (9.52)
1/2 (12.70)
Dimensions: H/W/D
mm
540/780/250
540/780/250
590/760/285
Weight
kg
29.50
29.50
35.0
From serial number
1306...
1308...
1310...
EDP no.
1633265
1633355
1633525
1)
Air inlet temp. TK 27°C / FK 19°C, outside temperature TK 35°C, FK 24°C, max. air flow volume,
5m pipe length
2)
Air inlet temp. TK 20°C, outside temperature TK 7°C, FK 6°C, max. air flow volume, 5m pipe length
3)
The specified value is based on results from standard testing.
The actual consumption depends on the use and location of the unit
4)
The specified value is based on the average heating period
5)
At distance of 1m in the open air; specified values are maximum values
6)
Contains greenhouse gas in accordance with the Kyoto protocol, GWP 1975 (for further information, see chapter "Adding refrigerant")
7)
This can be extended to -15°C with the appropriate accessory kit
9