3 connecting the outdoor unit, 4 electrical wiring diagram, Remko ml...dc – REMKO ML 263 DC User Manual
Page 34: Connecting the outdoor unit, Electrical wiring diagram
8.3
Connecting the outdoor unit
Proceed as follows to connect the line:
1.
Remove the side-panel cover.
2.
Choose a cable-section according to the rele-
vant specifications.
3.
Connect the lines as shown on the electrical
connection diagram.
4.
Fix the line in the strain relief and re-
assemble the unit.
Fig. 42: Connecting the outdoor unit
8.4
Electrical wiring diagram
Connection ML 263 DC-523 DC
230V/1~/50 Hz
L
N
PE
L(1) 1 2(N) S
L(1) 1 2(N) S
B
A
1
2
Fig. 43: Electrical wiring diagram
A:
Outdoor unit ML 263 DC AT-523 DC AT
B:
Indoor unit ML 263 DC IT-523 DC IT
1:
Power supply
2:
Communication line
REMKO ML...DC
34