beautypg.com

3 performance curves for heating and cooling, Performance curves for heating and cooling – REMKO ML 263 DC User Manual

Page 11

background image

2.3

Performance curves for heating and cooling

Heating capacity ML 263 DC

0,00

1,00

2,00

3,00

4,00

5,00

12

7

2

0

-7

-10

-15

2

1

3

A

[°C]

Fig. 3: Performance curves, heating ML 263 DC (data for 20 °C indoor temperature)

A:

Outside temperature

1:

COP

2:

Heating capacity in kW

3:

Power consumption in kW

Outside temp. in °C

12

7

2

0

-7

-10

-15

Heating capacity in kW

3.01

2.65

2.52

2.39

2.13

2.00

1.73

Power consumption in kW

0.69

0.68

1.14

1.08

1.01

1.01

0.95

COP

4.35

3.89

2.21

2.23

2.12

1.99

1.82

Cooling capacity ML 263 DC

0,00

0,50

1,00

1,50

2,00

2,50

3,00

3,50

4,00

21

25

30

35

40

45

50

2

1

3

A

[°C]

Fig. 4: Performance curves, cooling ML 263 DC (data for 27/19 °C indoor temperature)

A:

Outside temperature

1:

EER

2:

Cooling capacity in kW

3:

Power consumption in kW

Outside temp. in °C

21

25

30

35

40

45

50

Cooling capacity in kW

2.64

2.82

2.84

2.74

2.35

2.23

2.17

Power consumption in kW

0.74

0.80

0.87

0.95

0.96

0.98

1.02

EER

3.57

3.53

3.27

2.88

2.44

2.27

2.13

11

This manual is related to the following products: