beautypg.com

Post pulse resistance testing, Testing mode error/status conditions, Post pulse resistance testing -28 – Quantum Composers 9730 Series User Manual

Page 28: Testing mode error/status conditions -28

background image

9-28

Verify the rear panel Safety Interlock.

Turn Arm Switch to ‘ARM’ Position.

Press the FUNC key and then the PRE

key (‘.’ on the numeric keypad) to run the

pre pulse resistance test.

Refer to

Testing Mode Error Conditions

for more information on any resulting

errors.

Post Pulse Resistance Testing

The 9730 allows the user to setup a post pulse resistance test that, when enabled, may
be run at any time to verify the resistance of the connected load is greater than a user
specified minimum. To use pre pulse resistance testing:

Setup the system mode, period and channel pulse parameters as described in

the

Standard Operation Modes

section.

In the Channel Test Menu:

o Set P

stTest to ‘Enabled’

o Set PstMin to the minimum resistance

expected for a “fired” device.

Verify the rear panel Safety Interlock.

Turn Arm Switch to ‘ARM’ Position.

Press the FUNC key and then the POST

key (‘.’ on the numeric keypad) to run

the post pulse resistance test.

Refer to

Testing Mode Error Conditions

for more information on any resulting

errors.

Testing Mode Error/Status Conditions

Status -

“No Error Detected” – This message is returned through a channel

error query whenever no errors are detected for the current channel. Refer to

Channel Commands

for more information channel queries.