Bacnet® link interface technical guide 15, Vav/cav object – Orion System BACnet Link User Manual
Page 15
BACnet® Link Interface
Technical Guide
15
Object Properties For The VAV/CAV Controller
Property Name
Property Data Type
Property
Identifier
Read
Or
Write
Alarm_Status
VavAlarmBits
1024
R/O
Application_Software_Version
Unsigned
11
R/O
CO2_Setpoint
Real
1094
R/O
Control_Status
VavControlBits
1025
R/O
Control_Temperature
Real
1028
R/O
Cooling_Setpoint
Real
1027
R/O
Duct_Static_Pressure
Real
1090
R/O
Duct_Static_Setpoint
Real
1031
R/W
Economizer_Position
Real
1032
R/O
Fan_Speed_Unit
BACnetEngineeringUnits
1083
R/O
Heating_Setpoint
Real
1037
R/O
Humidity_Unit
BACnetEngineeringUnits
1084
R/O
Min_Outside_Air_Setpoint
Real
1091
R/W
Object_Identifier
BACnetObjectIdentifier
75
R/O
Object_Name
CharacterString
77
R/W
Object_Type
WattBacObjectTypes
79
R/O
Occupied_Cooling_Setpoint
Unsigned
1039
R/W
Occupied_Heating_Setpoint
Unsigned
1040
R/W
Outdoor_Air_Humidity
Real
1050
R/O
Outdoor_Air_Sensor_Offset
Real
1051
R/W
Outdoor_Air_Temperature
Real
1052
R/O
Outdoor_Air_Wetbulb
Real
1053
R/O
Position_Unit
BACnetEngineeringUnits
1085
R/O
Relays
VavRelayBits
1055
R/O
Relief_Pressure
Real
1056
R/O
Relief_Pressure_Setpoint
Real
1092
R/W
Return_Air_CO2_Level
Real
1093
R/O
Return_Air_Sensor_Offset
Real
1058
R/W
Return_Air_Temperature
Real
1057
R/O
Schedule_Force
WattBacScheduleState
1059
R/W
Space_Sensor_Offset
Real
1063
R/W
Space_Temperature
Real
1064
R/O
Staging_Deadband
Integer
1067
R/W
Supply_Air_Cooling_Setpoint
Unsigned
1068
R/W
Supply_Air_Heating_Setpoint
Unsigned
1069
R/W
Supply_Air_Sensor_Offset
Real
1071
R/W
Supply_Air_Temperature
Real
1073
R/O
Temperature_Demand
Real
1074
R/O
Temperature_Unit
BACnetEngineeringUnits
1086
R/O
Unoccupied_Coolting_Setpoint
Unsigned
1075
R/W
Unoccupied_Heating_Setpoint
Unsigned
1076
R/W
Vfd_Blower_Fan
Real
1077
R/O
Vfd_Exhaust_Fan
Real
1078
R/O
Warm_Up_Setpoint
Unsigned
1079
R/W
Wetbulb_Setpoint
Unsigned
1080
R/W
Table 8: VAV/CAV Object Properties
VAV/CAV Object
The information that follows describes the characteristics of the VAV/
CAV Object. The properties for the VAV/CAV Object are listed in Table
8.
Object Name
The Object Name for the VAV/CAV controller is a 15 byte character
string that can be set through the BACnet
®
front end.
Object Type
The Object Type of the VAV/CAV controller is VavCav or 257.
Object Instance Number
The Instance Number of the VAV/CAV Object is determined by two
variable values. The first variable is the loop address setting on the
BACnet
®
Link for the specific loop the VAV/CAV controller resides on
and the second is the VAV/CAV controller address. The BACnet
®
Link
loop address can be either 0, 1, 2 or 3. See Figure 3 at the front of this
manual for detailed information on the BACnet
®
Link loop address
jumper settings.
The second variable value used to calculate the Object Instance number
is the VAV/CAV controller address and is determined by the address
switch settings on the VAV/CAV controller. Valid address settings are 1
through 16.
See Table 10 at the end of this chapter for complete Object Instance
Number calculation information
Object Properties
The information and tables that follow detail the properties and prop-
erty identifiers for the VAV/CAV Object.