Components and wiring, Smts ii to vcm-x controller wiring, Smts ii technical guide – Orion System System Manager TS II In-House User Manual
Page 9: System manager ts back view

SMTS II Technical Guide
Components and Wiring
9
SMTS II to VCM-X Controller Wiring
Figure 6: System Manager TS II to VCM-X Controller Wiring
.1uF
YS102178 R4
WQVGA Graphical Interface
WattMaster Controls, Inc
C24
R9
R7
R6
R5
R2
R1
C51
C39
C20
C19
C15
C14
C13
C12
C11
C10
C9
C7
C1
X3
8.00
Mhz
OFF
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1
u
F
.1
u
F
.1uF
.1
u
F
.1
u
F
.1
u
F
.1
u
F
.1
u
F
.1
u
F
.1
u
F
.1
u
F
.1
u
F
.1uF
.1
u
F
.1
u
F
.1
u
F
.1
u
F
1002
.1uF
1002
1002
.1uF
.1uF
.1uF
.1uF
LTC3824
1002
1002
1002
1002
1002
1002
66.000Mhz
MADE IN USA
330uF 50V
330uF
1002
SERIAL #
OP
T
4
OP
T
3
OP
T
2
OP
T
1
TERM
RTC
YS102178 R4
WQVGA Graphical Interface
WattMaster Controls, Inc
CAL
5V
3.3V
2.5V
J3
R34
R
16
R13
R8
R39
X2
R26
R17
R14
C24
U13
R49
R48
R47
R46
R45
R44
R43
R40
R37
R35
R32
R31
R29
R27
R24
R22
R12
R11
R10
R9
R7
R6
R5
R2
R1
L5
L4
D12
D11
D1
C51
C50
C45
C41
C39
C36
C20
C19
C18
C17
C16
C15
C14
C13
C12
C11
C10
C9
C8
C7
C6
C5
C4
C1
J1
R41
C23
C25
C26
R42
X3
R20
C27
C34
C40
U10
U11
C28
C29
R18
C35
D2
L1
R25
C31
R19
U9
R28
C32
R
30
R33
C30
R15
Q2
R21
R23
SW1
C2
C3
V1
R36
1002
R
R
S
S
T
T
T
S
R
+
+
1002
R
T
5V
GND
System Manager TS
Back View
BLACK (R)
BLACK (R)
BLACK (R)
RED (24 VAC)
RED (24 VAC)
To (24 VAC)
Transformer +
T
o
R
T
erminal
On VCM-X
T
o
S
T
erminal
On VCM-X
T
o
T
T
erminal
On VCM-X
To (24 VAC)
Transformer -
BROWN (GND)
Line Voltage
24 VAC Transformer
5 VA Minimum
BROWN (GND)
WHITE (T)
WHITE (T)
WHITE (T)
BARE (S)
BARE (S)
BARE (S)
Run 2 Conductor
Twisted Pair W/Shield
Cable. WattMaster
WR-LL-WG-18 Cable
Or Equivalent From
System Manager To
VCM-X Controller
Run 2 Conductor 20 Ga. Minimum Cable From
System Manager TS Terminals To 24 VAC
TERM
NOTE: For Stand-Alone
Installations (No CommLink
or MiniLink), Both TERM
Jumpers Must Be ON.
For All Applications With
CommLink(s) Or MiniLink(s),
Both Jumpers Must Be OFF.
OFF
OP
T
4
OP
T
3
OP
T
2
OP
T
1
NOTE: Dip Switches OPT1,
OPT2 & OPT3
.
Should Be
Set To Off As Of April 2014,
OPT4 Should Be Set To ON
By Default. Previous Versions
Should Be Set To OFF. If You
See Your Screen Is Not
Centered Correctly, Switch
OPT4 To The Opposite
Position.
VCM-X Controller - Front View
AI1
AI1 SET
AI2 SET
AI3 SET
AI4 SET
AI5 SET
AI7 SET
AI2
AI3
AI4
AI5
AI7
Revised 4/21/14