minimum of 1875 watts.

Option #3 - Hardwire
1. Wire a dedicated, properly fused circuit with 120 Volt,

15 Amp

rating. Allow up to 8 feet of service cable for connecting power

supply to junction box on fireplace when installing after finishing

wall.

CAUTION: Use two conductor, non-metallic sheath cable with

ground wire (3 wires total) for the incoming power supply on

fireplace inserts. Use appropriate wire to meet local and

national electrical codes for rated power consumption.

2. Remove the outer jacket and strip the individual conductor from

the end.
3. Loosen the screw securing the junction box cover and remove

the cover.
4. Take the cables out from the junction box, loosen the two wire

twist nuts and remove the cord set. (Figure 3)

6

Figure 3

Figure 4

5. Route the power supply wire through the knockout on supplied

alternative junction box cover and secure with a wire clamp (not

supplied). (Figure 4)
6. Connect the black wire (live) from the unit to the black wire from