6.2

Putting into operation in daily operation

Depending on whether a partial or complete switching-off was performed, switching-on has to be
performed in reverse order (see also the exchange instructions for the individual devices).
Basically:

Atomiser BS5/10:
First connect the water supply and/or the compressed air supply (quick couplings). Then connect the
voltage supply (plug). Now you can set the set-point adjuster to the desired value again on types BS5
and 10.

6.3 Checks

When irregularities or malfunctions are detected during checks, inform the NORTEC customer
service at once! Checks may only be carried out by authorised staff. The operator is responsible for
checking the suitability of the staff and for instructing them.

6.3.1 Atomiser

BS5/10

Check the spray pattern. The ratio water consumption/compressed air consumption has a considerable
influence on the spray pattern. These parameters can be set on the device. Work settings may
never be changed without prior consultation of the NORTECcustomer service.

Cycle:

every

2

weeks

CAUTION: This check is necessary because it is possible to prevent damage when a very bad
atomising result is detected in time. The worse the atomising result, the bigger the drops. Drops
falling down may cause damage by corrosion.

In areas with a lot of dust and/or dirt formation, the functioning of the atomisers may be impaired.
Check this and remove the dirt, if necessary.

Deposits on the nozzles may impair the spray pattern. You can try to clean them as follows as an
emergency measure:

De-energise the device and switch off the stopcocks for air and water. Remove the knurled thumb
screw (3) and the air cap. Remove deposits at the tip of the nozzle (1) using a soft, lint-free cloth.
Never use a needle or similar solid objects for cleaning!





1 2 3


Cycle:

every

4

weeks


CAUTION:
Do not clean with water or any kind of cleaners, but only vacuum it. De-energise the
device and protect against switching on before cleaning.