Installation, Wiring, Page 13 c-series dv gas fireplace – Montigo C34DV User Manual
Page 13: Gas control and pilot wiring, Wiring for the optional fan kit, Figure 26

Page 13
C-Series DV Gas Fireplace
Part No. XG0170 - 080610
Installation
Wiring
Gas Control and Pilot Wiring
C-Series DV-I
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Fuse
Limit
Switch
Wall
Switch
Fan Plug
Receptacle
Junction Box
Junction Box Cover
White
Black
Green
40 VA
Transformer
115VAC
24VAC
Grnd Screw
Figure 26.
Wiring for the C-Series DV-I with Honeywell gas control and pilot.
Wiring for the optional Fan Kit
All C-Series DV fireplaces may be equipped with optional fan kits for
circulating heat into the living space.
Installations in Canada which employ the fans must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70-1987.
For more information see the Fan Kit Installation Guide included with
the fan kit.
NOTE:
If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
Figure 26b. Wiring schematic for optional fans.
Figure 26a. Wiring for optional fans.
115/1/60 Supply
G
L1 L2
G
L2-WH
L1-BLK
Quick Connect
plug to motor