Service – Montigo PVHFL58-300 User Manual
Page 19

Service
Page 19
XG0519 - 070714
Go to reinstalling either from outside or inside.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent
Step 13: Using the other supplied small bell connector, connect the brown
wire from the motor to the black wire of the capacitor.
Figure 10m.
Step 14: Secure the wiring neatly with the supplied zap straps. Check that
the power vent operates and spins counterclockwise. NOTE: When replacing
from inside you will need to reinstall the power vent and check spin from the
outside. Note: Ensure wires are secured away from moving parts
Figure 10n.
Step 12: Using the other supplied large bell connector, connect the white
fibre wire from the power cable to the black wire from the capacitor and the
black wire from the motor.
Figure 10l.