Installation, Wiring installation, Warning – Montigo EDVRSPV47 User Manual
Page 7: 1" min. vent cable

EDVRSPV Vertical Power Vent System
Part No. XG1302 - 120110
f i r e f e a t u r e
Installation
WARNING
:
Montigo will not be held responsible for any wa-
ter damage that may occur from not installing the
equipment as specified by this document.
Step 7.
Install the Power Vent Module. Place the Power Vent Module
over the stainless steel cover flange and vent pipe, aligning the
Power Vent into final position. Ensure the Harness is placed
down in the Rough-in box when placing the Power Vent Module
into place. The Power Vent Module will sit flush with the stainless
steel cover if installed correctly.
Install Power Vent
Module, with Power
/ Communication
harness.
Figure 10. (Installation of Power Vent Module)
Figure 11. (Installed Power Vent Module)
Step 8.
Install (3) three stainless steel fasteners around Power Vent
Module @120 degrees (penetrating through the inner stainless
steel vent cover)
Figure 11. Conduit and Wiring Clearances.
Wiring Installation
Connect the wiring to the external power vent termination as outlined
in the previous section, and connect the wiring to the fireplace as
outlined in the schematic below. Ensure that the proper clearances are
maintaned for the wiring and conduit.
■
When installing the wiring it must never run above the vent run
and it must be at least 1" clear of all venting.
1" min.
Vent
Cable
Figure 12. Wiring Diagram for Power Vent System.
Control Cable Installation
for Vertical Termination
EXPVH 10 - 100.
Honeywell
SV9501M
PPO
Box
Power Vent
EDVRP47
PVFCB
ECB005
Pilot
Inside Fireplace
Wall Switch
120V
Page 7