Maintenance – Montigo 34FID - Linear User Manual
Page 50

Page 50
XG0514-150204
I-Series Indoor Gas Fireplace
Maintenance
12). Install both new Blowers. Secure the Wire Harness with the Zip
Straps shown in the 2 pictures below.
Figure 22 Sec.6
1
3). At this point, if you want to test the Blower operation, do so
with the Gas Supply turned off or disconnected. To test the Blower
operation, you will need to re-connect the electrical supply temporarily.
Disconnect the Electrical Supply after testing the Blowers.
Figure 23 Sec.6
14). Re-install the Outer Shell Rear panel.
15). You will need to replace the Flue Collar Plate Gasket prior to
re-installation into the cavity.
Figure 24 Sec.6
16). Replace the Flue Connector Plate Gasket.
17). Re-install the unit into the Cavity. See the section on Vent
Connections.
18). Re-install the Face Plate Panels. See the section on Setup.
19). Re-connect the Electrical Supply.
- H36PVN (40 pages)
- H42VO (22 pages)
- L38DF (40 pages)
- L42DF (40 pages)
- HL34DF (42 pages)
- P42DF (34 pages)
- R820 (44 pages)
- P52DF (34 pages)
- Flush Face (DF) Door Removal (1 page)
- Flush Face (DF) (14 pages)
- B38DV (26 pages)
- L52DF-ST (34 pages)
- HL38DF ST (38 pages)
- HL42DF ST (36 pages)
- RP620 (48 pages)
- HL38SVO-ST (20 pages)
- HP38DF-CLCR (38 pages)
- HP38DF PFC (38 pages)
- HP38DF PRC (38 pages)
- R620-ST (38 pages)
- DHS (22 pages)
- R324-ST (22 pages)
- 34FID Traditional (70 pages)
- 1001-A (6 pages)
- 1001 TH-A (9 pages)
- PF2RK (4 pages)
- RX100 (6 pages)
- H42 (2 pages)
- RX82 (12 pages)
- RX200 (8 pages)
- HFK-Series Cross-Flow Blower (2 pages)
- P-Series Fireplace Surround (2 pages)
- RX88 (20 pages)
- HFK50R (2 pages)
- RFK1080 (2 pages)
- HFK50 (4 pages)
- IOSK3 (2 pages)
- IOSK4 (2 pages)
- IOSK5 (2 pages)
- IOSK6 (2 pages)
- RFK3004 (4 pages)
- RFK3004R (4 pages)
- EPVRW (6 pages)
- EPVRR (6 pages)