beautypg.com

Installation – Montigo L38DF-ST User Manual

Page 12

background image

L38DF-ST* Indoor Gas Fireplace

Page 12

XG0810 - 150204.2

Installation

1

12”

2”

12”

12”

Section 3-3: Installing a Wall Mounted Direct

Vent Termination

This section applies to installations where the direct vent termi-

nation will be wall mounted.

Installation of Termination with built in frame
A Termination with a Built-In Frame is installed during framing of a

structure.

1. Frame the termination opening to 11" x 11".
2. Install exterior sheathing to the structure framing.
3. Fasten the termination to the sheathing using a minimum of 4 screws.

MSR Frame

PTO-4 (5"/8")

Termination

PTO-4F (5"/8")

Termination

Figure 10. Installing a PTO4-F termination.

Figure 10a. Installing a PTO termination with the MSR frame.

Figure 10d. Installing the VSS Vinyl Shield.

Installation of a termination shield for Vinyl Siding
The VSS Termination shield is installed when the exterior of a struc-

ture is clad with Vinyl siding. It is placed directly above, and on-center

with the termination.

Installation of termination frame at time of framing
Terminations with a MSR frame allow the installation of the frame

prior to installation of the termination.

1. Frame the termination opening to 12" x 12".
2. Secure the MSR Frame to the exterior sheathing of the structure.
3. Fasten the termination to the MSR Frame using a minimum of 4 screws.

Figure 10b. Installing a PTO termination with the BSR frame.

1. Frame the MOSR opening to 12" x 12".
2. Fasten the MOSR frame to the interior side of the studs, con-

crete, or finished wall construction using a minimum of 4 screws.

3. Insert the termination into the MOSR frame as shown here, (from

the inside) and attach to the MOSR by installing a min. quantity

of 4 bolts into the threaded nuts on the MOSR Frame.

Installation of termination frame at time of framing in Masonry
Terminations with a BSR frame allow the installation of the frame in

masonry prior to the installation of the termination

1. Frame the BSR opening to 12" x 12".
2. Secure the BSR Frame to the exterior sheathing of the structure.
3. Fasten the termination to the BSR Frame using a minimum of 4 screws.

BSR Frame

MTKOG (5"/8")

Installing Heat Guards over Terminations is recommended in installa-

tions where the termination is located within 7' feet above grade, or

above a pedestrian walkway, and may be Required by code in Public

areas.

1. Ensure that the two long mounting brackets are facing the bot-

tom of the termination. (See inset). This will provide more heat

protection at the top of the termination, where temperatures are

highest.

2. Attach to the faceplate of the termination using four sheet metal

screws.

Figure 11. Installing a PTO termination heat guard.

11”

11”

Framing

Exterior

Sheathing

Fastening Hardware,

minimum 4-screws

Framing

Exterior

Sheathing

Fastening Hardware,

minimum 4-screws

PTO-4 (5"/8")

Termination

Framing

Exterior

Sheathing

Fastening Hardware,

minimum 4-screws

Exterior Vinyl

siding

PTO-4 (5"/8")

Termination

VSS Vinyl shield

Installation of termination from inside structure

A Termination with a MOSR Frame is installed from the inside of the

structure. These are commonly used in high-rise construction.

MOSR Frame

PTO-4 (5"/8")

Termination

Figure 10c. Installing a PTO termination with MOSR frame.

12”

12”

Fastening Hardware,

minimum 4-screws

Framing,

concrete or

other

materials

Exterior

Sheathing,

concrete or

other materials

This manual is related to the following products: