Specifications

External power input

Table 3. External power input specifications

Parameter Conditions

Specification

External power input

+6.0 VDC to 12.5 VDC (9 VDC
power supply included)

6.0 V > Vext or Vext > 12.5 V

PWR LED = Off (power fault)

Voltage supervisor limits - PWR LED
(Note 1)

6.0 V < Vext < 12.5 V

PWR LED = On

External power adapter (included)

MCC p/n CB-PWR-9

+9 V ±10%, @ 1 A

Note 1:

The USB-ERB08 monitors the external +9 V power supply voltage with a voltage supervisory
circuit. If this power supply exceeds its specified limit, the PWR LED will turn off indicating a
power fault condition.

External power output

Table 4. External power output specifications

Parameter Conditions

Specification

External power output - current range

4.0 A max.

External power output (Note 2)

Voltage drop between power input and daisy
chain power output

0.5 V max

Compatible cable(s) for daisy chain

C-MAPWR-x

x = 2 , 3, or 6 feet

Note 2:

The daisy chain power output option allows multiple Measurement Computing USB boards to be
powered from a single external power source in a daisy chain fashion. The voltage drop between
the module power supply input and the daisy chain output is 0.5 V max. Users must plan for this
drop to ensure the last module in the chain will receive at least 6.0 VDC.

USB specifications

Table 5. USB specifications

USB "B" connector

Input

USB device type

USB 2.0 (full-speed)

Device compatibility

USB 1.1, USB 2.0

USB "A" connector

Downstream hub output port
Supports USB 2.0 high-speed, full-speed and low-speed operating points

USB hub type

Self-powered, 100 mA max downstream VBUS capability

Compatible products

MCC USB Series devices

USB cable type (upstream and downstream)

A-B cable, UL type AWM 2527 or equivalent.
(min 24 AWG VBUS/GND, min 28 AWG D+/D-)

USB cable length

3 meters max.

Relay contact pull-up/down option

Table 6. Relay pull-up/pull-down specifications

R1, R3, R5, R7, R10, R12, R14, R16

Relays NO contact pull-up (to USB +5V) / pull-down

R2, R4, R6, R8, R9, R11, R13, R15

Relays NC contact pull-up (to USB +5V) / pull-down

4-2