Network

Ethernet connection

Table 16. Ethernet connection specifications

Parameter

Specification

Ethernet type

100 Base-TX
10 Base-T

Communication rates

10/100 Mbps, auto-negotiated

Connector

RJ-45, 8 position

Cable length

100 meters max

Additional parameters

HP Auto-MDIX support

Network interface

Table 17. Factory default specifications

Parameter

Specification

Protocols used

TCP/IP (IPv4 only), UDP

Network ports used

UDP:54211 (discovery)
UDP:6234 (bootloader only)
TCP:54211 (commands)
TCP:54212 (scan data)

Network IP configuration

DHCP + link-local, DHCP, static, link-local

Network name

E-1608-xxxxxx, where xxxxxx are the lower 6 digits of the device MAC address

Network name publication

By NBNS (responds to b-node broadcasts, therefore only available on the local
subnet)

Network factory default settings

Table 18. Factory default specifications

Parameter

Specification

Factory default IP address

192.168.0.101

Factory default subnet mask

255.255.255.0

Factory default Gateway

192.168.0.1

Factory default DHCP setting

DHCP + link-local enabled

Network security

Table 19. Factory default specifications

Parameter

Specification

Security implementation

TCP sockets are not opened unless application sends the correct PIN code (stored in
non-volatile memory, may be changed by user, default value 0000)

Number of concurrent sessions

1

Vulnerabilities

TCP Sequence Number Approximation Vulnerability