6K-ERB08 User's Guide

Installing the 6K-ERB08

Details on the C50FF-x cable are available on our web site at

www.mccdaq.com/cbicatalog/cbiproduct.asp?dept_id=104&pf_id=136

.

Connecting to your 6000 Series control board

The following procedure provides the general steps to follow to connect your 6K-ERB08 to a PCI-DAS6000
Series board or to a PCI-DAC6700 Series board.

1.
2.

3.

o

o

Turn off your computer and open the cover.
Install your PCI-DAS6000 Series or PCI-DAC6700 Series board in the computer. Refer to your board’s
hardware User Guide for installation instructions.
Connect the digital signal cable from one of the interface connectors on the 6K-ERB08 to the 100-pin
interface connector on your 6000 Series control board. Your signal cable determines which interface
connector to connect to.

C100MMS-x

cable: Connect one end of the cable to either 100-pin interface connector (

P21

or

P20

)

on the 6K-ERB08, and connect the other end of the cable to the 100-pin interface connector on the
6000 Series control board.

C100HD50-x

cable: Connect the 50-pin cable end stamped

Pins 51 to 100

to either 50-pin connector

(

P6

or

P5

) on the 6K-ERB08, and connect the 100-pin cable end to the 100-pin interface connector on

the 6000 Series control board.

External power is required when using the C100HD50-x cable
The C100HD50-x cable does not provide power to the 6K-ERB08. If you use the C100HD50-x cable, power
the 6K-ERB08 with an external power source.

4.

o

o

To connect other accessory boards or devices to your 6K-ERB08, use the remaining 100-pin interface
connector and/or the two 50-pin connectors for the connection(s). The following typical configurations are
possible:

When using a C100MMS-x cable, you can use a second C100MMS-x cable to daisy chain to an SCB-
100 accessory board, OR you could use a C50FF-x cable to daisy chain to a 50-pin accessory board.
When using a C100HD50-x cable, you can use a C50FF-x cable to daisy chain to a 50-pin accessory
board.

Configuring your 6K-ERB08 board

Configure the power source jumper and relay logic jumper before using the 6K-ERB08. The factory-configured
default settings are listed in T

.

able 2-6

Table 2-6. Default hardware configuration

Jumper label

Jumper description

Default setting

POWER IN
JP1

Sets the power source to one of three options:
ƒ

+5BD: +5V power from your 6000 Series control board.

ƒ

+5PC: +5V power from the computer’s power supply.

ƒ

+9V EXT: power from an AC adapter.

+5BD

INVERT / NON-INVERT
JP2

Sets the relay logic for active high or active low.

NON-INVERT
(active high)

Figure 2-4 shows the location of the jumpers and external power connectors.

2-8