Performance, Spray pattern and reach (typical 21’ spray bar), Typical spray system duration – MEGA Corp. MTT-OPS-1 User Manual
Page 36: Section 5 performance -1
![background image](https://www.manualsdir.com/files/797340/content/doc036.png)
5-1
MTT-OPS-1
13 Nov 2013
SECTION 5
Performance
Contents
SPRAY PATTERN AND REACH (TYPICAL 21’ SPRAY BAR)
The figures below illustrate width and reach of spray heads and monitor. Typical spray head deflector fan
adjustments are also depicted.
TYPICAL SPRAY SYSTEM DURATION
The table below contains a standard vehicle spray duration based on spray head deflector opening, vehicle
speed and 75,708 liter (20,000 gallon) capacity.
Number of Spray Heads
and Opening Width
LPM/GPM
Ground Speed
(KPH/MPH)
Max. Distance
(Km./Miles)
2 Spray Heads@ 1/4”
3611/954
16/10
5.6/3.5
2 Spray Heads@ 1/4”
3611/954
24/15
8.3/5.2
2 Spray Heads@ 3/8”
4705/1243
16/10
4.3/2.7
2 Spray Heads@ 3/8”
4705/1243
24/15
6.4/4.0
4 Spray heads @ 1/4”
5693/1504
16/10
3.5/2.2
4 Spray heads @ 1/4”
5693/1504
24/15
5.3/3.3
4 Spray heads @ 3/8”
5950/1572
16/10
3.3/2.1
4 Spray heads @ 3/8”
5950/1572
24/15
5.1/3.2
Spray Pattern and Reach .............................................5-1
Typical Spray System Duration ..................................5-1
Precision Watering ........................................................ 5-2