beautypg.com

Cab control system (analog), System description, Mtt-ops-1 – MEGA Corp. MTT-OPS-1 User Manual

Page 13

background image

MTT-OPS-1

13 Nov 2013

SECTION 2

System Description

2-4

CAB CONTROL SYSTEM (ANALOG)

Multi-function control box that is mounted in the
vehicle cab to control all water tank functions.
Controls are available for the monitor, intermittent
spray, water pump, work lights, foam suppression,
adjustable nozzle, system, spray heads, spray bar,
gravity dump bar and tank drain valve. The control
box also provides indications of tanker water level
and a system fuse holder. The cab controls requires
24 VDC vehicle power to operate.

There are several different configurations of the in-
cab control boxes. Each box is designed and
mounted for a specific prime mover. These
configurations are as follows:

The control functions operate as follows:

 

Standard

Step Box

Coffin Box

Control

Function

Joystick

Sends command signals to the
logic box (electric monitor) or
hydraulic control valve assembly
(hydraulic monitor) to move the
monitor left, right, up and down.

TIMER ON

Sets ON time (variable adjust-
ment 5-100 sec) of selected spray
heads and dump bar when the
timer switch is in the intermittent
position

TIMER OFF

Sets OFF time (variable adjust-
ment 5-100 sec) between timer
cycles of selected spray heads
and dump bar when the timer
switch is in the intermittent posi-
tion.

PUMP

Routes vehicle hydraulic system
pressure and flow to the water
pump hydraulic drive motor.

MONITOR

Opens the water cannon BFV.

LIGHTS

Provides power to work lights.

FOAM

Open or closes the foam concen-
trate tank in-line control valve.

INTERMITTENT/
CONSTANT

Activates or deactivates system
timer function.

AUX

Reserved for specialized func-
tions.

ADJUSTABLE
NOZZLE

Adjusts monitor nozzle from
FOG/FAN to STREAM.

AUX

Reserved for specialized func-
tions.

WATER LEVEL

Indicates tank water level.

SYSTEM

Provides power for all cab control
functions.

LT BUMPER

Opens or closes left front bumper
spray head.

LT VSS

Opens or closes left vertical side
spray head.

LT REAR

Opens or closes left rear spray
head.

This manual is related to the following products: