Operations, Normal operations – MEGA Corp. MTT-OPS-1 User Manual
Page 29

MTT-OPS-1
13 Nov 2013
SECTION 4
Normal Operations
4-2
OPERATIONS
Use these procedures to safely operate the standard
and optional systems installed on the MEGA water
tanker.
Limit water pump operation to 2.5 minutes when in a
no-flow condition (not flowing water through spray
heads, dump bar, monitor, drain valve or hose reel).
Water pump operation in a no flow condition will
cause overheating of the water pump and damage to
the shaft bearings and seals.
SPRAY HEAD SYSTEM
Operating more than 4 spray heads simultaneously
will greatly reduce the width and flow of active spray
heads.
1. Cab Control SYSTEM/POWER Switch – ON
2. INTERMITTENT TIMER – SET
a. TIMER ON/OFF Dials – SET
b. INTERMITTENT Switch – SET
3. PUMP Switch – ON
Engaging/disengaging the water pump above
LOW IDLE may result in water pump component
damage and reduced service life.
4. Individual Spray Heads – SELECTED
Once operations are complete:
5. PUMP Switch – OFF
Engaging/disengaging the water pump above
LOW IDLE may result in water pump component
damage and reduced service life.
6. Cab Control SYSTEM/POWER Switch – OFF
GPS AUTO MODE
1. Cab Control POWER Switch – ON
2. PUMP Switch ON
Engaging/disengaging the water pump above
LOW IDLE may result in water pump component
damage and reduced service life.
3. AUTO – SET AS REQUIRED
a. RATE and SPEED Dials – SET
b. AUTO Switch – ON
4. Individual Spray Head Switches – ON
Once operations are complete:
5. Individual Spray Head Switches – OFF
6. PUMP Switch – OFF
Engaging/disengaging the water pump above
LOW IDLE may result in water pump component
damage and reduced service life.
7. Cab Control POWER Switch - OFF
DUMP BAR
1. Cab Control SYSTEM/POWER Switch – ON
2. INTERMITTENT – SET AS REQUIRED
a. TIMER ON/OFF Dials – SET
b. INTERMITTENT Switch – SET
3. PUMP Switch – ON
Engaging/disengaging the water pump above
LOW IDLE may result in water pump component
damage and reduced service life.
4. DUMP Bar Switch – ON